| Subculture procedure | 1. Experimental preparation: dissolve various components in the kit on ice before use, mix slightly and centrifuge briefly, and then place them on ice for later use; 2. Sample processing: sample processing shall be carried out according to SN/Campylobacter T3639-2013 jejuni test; 3. Reagent preparation: experimental reaction system (25 μL),qPCR mixed reaction solution 21 μL, template 4 μL; 4. Reaction conditions: 95 ℃ 3min 1cycle;94 ℃ 10s, 50 ℃ 30s 40cycle; 5. Fluorescence channel: FAM; |
| Storage conditions | -20 ℃; Keep away from light |
| Safety level | 1 |
| application | It is suitable for auxiliary diagnosis of Campylobacter jejunum (CJ) infection in water-like feces, suspected contaminated water, food and other samples. |
| Sharing mode | Public welfare sharing |
Campylobacter jejuni nucleic acid test kit certificate
1. Product information
Sample name: Campylobacter jejuni (CJ) nucleic acid detection kit (fluorescent PCR method)
Sample number: 360690
Sample batch: 220401
2. Product features
| Reagent composition | reaction solution 525μL/tube, positive quality control 100μL/tube, negative quality control 100μL/tube |
| traceability | Campylobacter ATCC33291 jejuni (CJ), Campylobacter Colon ATCC43478 |
| save and transport | -20 ℃, valid for 1 year, dry ice transportation |
| applicable fields | It is suitable for auxiliary diagnosis of Campylobacter jejunum infection in water-like feces, suspected contaminated water, food and other samples |
| *Note: If you have any questions about this kit, please contact our center (BNCC) for help before use | |
3. Use steps
1. Experiment preparation: Dissolve the various components in the kit on ice before use, mix gently and centrifuge briefly, then place on ice for later use;
2. Sample processing: sample processing according to "SN/T3639-2013 Campylobacter jejuni test";
3. Reagent preparation: experimental reaction system (25 μL), 21 μL qPCR mixed reaction solution, 4 μL template;
4. Reaction conditions: 95°C 3min 1cycle; 94°C 10s, 50°C 30s 40cycle;
5.Fluorescence channel: FAM;
4.Result judgment
1. The sample has a typical amplification curve, and the Ct value is less than or equal to 35;
2. The sample has no amplification curve, and the Ct value is ≥40 or not detected;
3. If the t value of the sample is >35 and <40, it needs to be re-measured. Retest results Ct value ≥ 40 is negative, Ct value < 40 is positive.
5. Storage and transport
1. The various components in the kit were dissolved on ice before use, completely mixed and centrifuged briefly, and then placed on ice for later use;
2.In order to ensure the sensitivity of the detection, it is recommended that the qPCR mixed reaction solution be frozen and thawed no more than 3 times;
3.Sample processing, reagent preparation, and sample addition should be performed in different areas to avoid cross-contamination;
Henan Engineering Research Center of Industrial Microbial Strain
website: www.bncc .org .cn tel: 400-6699-833
Campylobacter jejuni (CJ) nucleic acid detection kit (Fluorescent PCR method)(Campylobacter jejuni (CJ) nucleic acid detection kit (Fluorescent PCR method))
BNCC360690
Campylobacter jejuni (CJ) nucleic acid detection kit (Fluorescent PCR method)(Campylobacter jejuni (CJ) nucleic acid detection kit (Fluorescent PCR method))
BNCC360690