BeNa Culture Collection
info@bncc.com
| Growth conditions | 37 ℃; 18-24h; aerobic; |
| Storage conditions | -20 ℃ |
| Safety level | 1 |
| morphology | The colony diameter is 1-2mm, circular, with neat edges, opaque, gray white on the front, raised in the middle, smooth on the surface, bright on the surface, moist texture, easy to pick up, producing green pigment, G - (red), Bacillus |
| Sharing mode | Public welfare sharing |
Pseudomonas aeruginosa
Strain number: BNCC 125486 / CMCC10104
Product format: quantitative bacteria tablets 50- 100CFU、bottle
Product batch:22011201
Date of inspection:2022.01.13
Valid until:2023.01.11
Number of viable bacteria:(75±25)CFU/bottle
Sampling ratio:≥2%
Report number: RS22125486-1
Biosafety level: 2, handle in ultra-clear table
| Items | test results | description |
| stain microscopy | gram negative and positive, cell morphology observed under microscope | G + bacilli |
| colony morphology | observation of single colony morphology | light yellow, moist, raised, with neat edges |
| purity | non-selective medium culture, colony observation and microscopic examination | No bacteria |
| Reference value of live bacteria | Non-selective medium plate, viable count | 63CFU/bottle |
| Phenotypic and Genotypic Analysis | phenotypic testing, gene sequencing | qualified |
| test conclusion | after quality inspection by BNCC quality control testing system, the product is qualified |
Product list: (75±25)CFU/bottle ,1 bottle of 50-100CFU quantitative strain, 1 bottle of 1mL lysate, 1 strain certificate;
Validity period: unopened, below -20 ℃, 12 months;
Usage:
1. Open the strain and dissolved solution according to the arrow of Xilin bottle cap;
2. Pour the bacteria tablets into the dissolved liquid, cover the rubber stopper, shake and dissolve;
3. After fully dissolved, it is (75±25)CFU/mL, absorbed in proportion according to the test requirements;
4. Please use up immediately after opening, and do not store it;
Notes:
① This product is a quantitative strain. Improper storage conditions and use methods will affect the accuracy of the number of strains, so please operate in strict accordance with the above storage conditions and methods.
②Used germ-carrying consumables should be discarded after autoclaving.
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
388968
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
367732
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
370081
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
382371
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
353739
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
359609