BeNa Culture Collection
info@bncc.com
| Growth conditions | 37 ℃; 18-24h; Aerobic |
| Storage conditions | -20 ℃ |
| Safety level | 1 |
| morphology | The colony diameter is 0.5-1mm, circular, with neat edges, opaque, gray white on the front, raised in the middle, bright and smooth on the surface, moist texture, easy to pick up, G - (red), Bacillus |
| Sharing mode | Public welfare sharing |
Pseudomonas aeruginosa
Strain number: BNCC 354700 / CMCC10104
Name: Pseudomonas aeruginosa
Product format: quantitative bacteria tablets Number of viable bacteria:0.5- 1.0x105CFU/bottle
Product batch: 220322 Valid until: 2024.03.21
Inspection date: 2022.03.23 Sampling ratio: ≥2%
Report number: RS22354967-1 Biosafety level: 1, handle in ultra-clear table or safety cabinet
| Item | Inspection description | results |
| stain microscopy | gram negative and positive, cell morphology observed under microscope | G-bacilli |
| colony morphology | observation of single colony morphology | light yellow, smooth, moist, raised |
| Purity | non-selective medium culture, colony observation and microscopic examination | No contaminated bacterial |
| Reference value of live bacteria | Non-selective medium plate, viable count | 72917CFU/bottle |
| Phenotypic and Genotypic Analysis | phenotypic testing, gene sequencing | qualified |
| test conclusion | After the BNCC quality control inspection system quality inspection, the product is qualified | |
Product list: 0.5- 1.0x105CFU quantitative strain 1 bottle, 1mL dissolved solution 1 bottle, strain certificate 1;
Validity period: unopened, below -20 ℃, 12 months;
Usage:
1. Open the strain and dissolved solution according to the arrow of Xilin bottle cap;
2. Pour the bacteria tablets into the dissolved liquid, cover the rubber stopper, shake and dissolve;
3. After fully dissolved, it is 0.5- 1.0x105CFU/bottle, which can be sucked in proportion according to the test requirements;
4. Please use up immediately after opening, and do not store it;
Notes:
① This product is a quantitative strain. improper storage conditions and usage methods will affect the accuracy of the number of strains, so please strictly follow the above storage conditions and methods.
② Used bacteria-carrying consumables, please autoclave and discard them.
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
388968
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
367732
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
370081
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
382371
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
353739
Quantitative strains of pseudomonas aeruginosa(Quantitative strains of pseudomonas aeruginosa)
359609